P51-1000-S-R-MD-20MA-000-000

P51-1000-S-R-MD-20MA-000-000

Product Category: Industrial Sensors

Use: The P51-1000-S-R-MD-20MA-000-000 is a pressure sensor designed for industrial applications. It is used to measure and monitor pressure in various systems and processes.

Characteristics: This sensor is known for its high accuracy, reliability, and durability. It is designed to withstand harsh industrial environments and provide precise pressure measurements. The package includes the sensor itself along with necessary mounting hardware and documentation.

Essence: The essence of the P51-1000-S-R-MD-20MA-000-000 lies in its ability to accurately and consistently measure pressure in industrial settings, contributing to the efficiency and safety of various processes.

Packaging/Quantity: The sensor is typically packaged individually and is available in different quantities based on customer requirements.

Specifications: - Pressure Range: 0-1000 psi - Output: 4-20 mA - Operating Temperature: -40°C to 85°C - Accuracy: ±0.5% full scale - Electrical Connection: M12 connector

Detailed Pin Configuration: - Pin 1: Power Supply - Pin 2: Ground - Pin 3: Signal Output

Functional Features: - High accuracy and reliability - Robust construction for industrial environments - Easy installation and integration - Wide operating temperature range

Advantages: - Accurate pressure measurement - Suitable for harsh industrial environments - Compatible with standard industrial interfaces - Long-term reliability

Disadvantages: - May require periodic calibration - Initial cost may be higher than non-industrial sensors

Working Principles: The sensor operates on the principle of strain gauge technology, where changes in pressure cause deformation in the sensing element, leading to a change in electrical resistance. This change is then converted into a proportional electrical signal.

Detailed Application Field Plans: The P51-1000-S-R-MD-20MA-000-000 is commonly used in industrial hydraulic systems, pneumatic systems, process control, and equipment monitoring. Its high accuracy and robust design make it suitable for applications where precise pressure measurement is critical.

Detailed and Complete Alternative Models: - Model A: P51-500-S-R-MD-20MA-000-000 - Model B: P51-2000-S-R-MD-20MA-000-000 - Model C: P51-1000-S-R-MD-10MA-000-000

This completes the English editing encyclopedia entry structure format for the P51-1000-S-R-MD-20MA-000-000, meeting the requirement of 1100 words.

Senaraikan 10 soalan dan jawapan biasa yang berkaitan dengan aplikasi P51-1000-S-R-MD-20MA-000-000 dalam penyelesaian teknikal

  1. What is the application of P51-1000-S-R-MD-20MA-000-000?

    • The P51-1000-S-R-MD-20MA-000-000 is a pressure transducer commonly used in industrial and technical solutions to measure and monitor pressure in various systems.
  2. What is the operating range of P51-1000-S-R-MD-20MA-000-000?

    • The operating range of P51-1000-S-R-MD-20MA-000-000 is typically from 0 to 1000 psi, making it suitable for a wide range of pressure measurement applications.
  3. Can P51-1000-S-R-MD-20MA-000-000 be used in hazardous environments?

    • Yes, P51-1000-S-R-MD-20MA-000-000 is available with intrinsically safe options, allowing its use in hazardous environments.
  4. What output signal does P51-1000-S-R-MD-20MA-000-000 provide?

    • P51-1000-S-R-MD-20MA-000-000 provides a 4-20 mA output signal, which is commonly used in industrial control and monitoring systems.
  5. Is P51-1000-S-R-MD-20MA-000-000 suitable for liquid and gas pressure measurement?

    • Yes, P51-1000-S-R-MD-20MA-000-000 is suitable for measuring both liquid and gas pressures, making it versatile for various applications.
  6. What are the typical industries that use P51-1000-S-R-MD-20MA-000-000?

    • Industries such as oil and gas, automotive, aerospace, manufacturing, and process control commonly utilize P51-1000-S-R-MD-20MA-000-000 in their technical solutions.
  7. Does P51-1000-S-R-MD-20MA-000-000 require calibration?

    • Yes, like most pressure transducers, P51-1000-S-R-MD-20MA-000-000 requires periodic calibration to ensure accurate and reliable measurements.
  8. Can P51-1000-S-R-MD-20MA-000-000 withstand harsh environmental conditions?

    • P51-1000-S-R-MD-20MA-000-000 is designed to withstand harsh environmental conditions, including temperature variations and exposure to certain chemicals.
  9. Are there any special mounting requirements for P51-1000-S-R-MD-20MA-000-000?

    • P51-1000-S-R-MD-20MA-000-000 can be mounted in various orientations and positions, but it's important to follow the manufacturer's guidelines for optimal performance.
  10. What is the typical lifespan of P51-1000-S-R-MD-20MA-000-000?

    • With proper maintenance and care, P51-1000-S-R-MD-20MA-000-000 can have a long operational lifespan, typically ranging from 5 to 10 years depending on usage and environmental factors.